Skip to main content

How to export an IFC model with spaces for Visibuild

Best practice for .ifc file export to get the most out of your model in Visibuild.

Written by Benjamin Martin

Visibuild links your locations to the rooms in an IFC model, so the model must include its rooms as IfcSpace. Most models that arrive without rooms still have them in the design software: the export settings left them out.

This article shows how to export rooms from Revit and Archicad, what to check in other tools, and how to test the file with the Visibuild IDS file before you upload it. If someone else exports your model, usually the architect's BIM manager, send them this article and the IDS file.

Why rooms matter

Without IfcSpace, Visibuild can link and colour whole levels only. You lose room-by-room progress, and Visibuild has no rooms to suggest links for.

Visibuild uses

From the IFC model

What it does

Levels

IfcBuildingStorey, with a name

Links your level locations. Each level shows as a plate in Simple view.

Rooms

IfcSpace

Links your room locations. Each room shows as a block coloured by progress.

Room number

IfcSpace Name

Used with the room name to suggest links.

Room name

IfcSpace LongName

Used with the room number to suggest links.

Room shape

IfcSpace 3D geometry

Draws the room so it can be coloured.

Suggestions work best when room numbers and names in the model match your location names, for example L02.173 Ward Bedroom in both.

Before you export

Check these in the design model first. An export cannot add rooms the model does not have.

  • Send the architectural model. Structural, services and fabrication models do not hold rooms. A federated model is much larger and usually adds nothing Visibuild needs.

  • Place a room in every area you want to track. In Revit these are Rooms; in Archicad they are Zones. Include corridors, risers, plant rooms and balconies if work is inspected there.

  • Number and name every room. Use the numbers and names the builder uses on site, so they match the Visibuild locations.

  • Close every room boundary. Rooms that are not enclosed or not placed export without a shape, or not at all.

  • Set up levels. In Revit, tick Building Story on each level that should appear in the IFC.

  • Export rooms only, not area plans. Area take-offs such as GFA or NLA zones also export as spaces. They overlap your rooms and make linking harder.

  • Export one building per file. Visibuild links each model to one building location.

  • Use a supported file. IFC2x3 or IFC4, as .ifc, .ifcxml or .ifczip, up to 2 GB.

Export from Revit

Revit exports Rooms as IfcSpace, with Room Number as the IFC Name and Room Name as the LongName. The most common reason rooms go missing is exporting from a 3D view: rooms are not visible in 3D, so a view-based export leaves them out unless you turn on one setting.

  1. Go to File > Export > IFC.

  2. Pick a setup to start from: IFC 2x3 Coordination View 2.0 or IFC4 Reference View. Select Modify setup, then duplicate the setup and name it, for example Visibuild rooms. Changes to the In-Session Setup are lost when you close Revit.

  3. On the General tab, set Phase to export to the phase your rooms belong to, usually the last phase. Leave Space boundaries at None; Visibuild does not use them.

  4. Still on General, open Category Mapping. Check that Rooms maps to IfcSpace. Set Areas, and Spaces if the model has MEP spaces, to Not Exported so only rooms come through. In Revit 2023 and earlier, this mapping is under File > Export > Options > IFC Options.

  5. On the Additional Content tab, choose one:

    • To export the whole model, clear Export only elements visible in view.

    • To export from a 3D view, keep it ticked and also tick Export rooms in 3D views. Rooms inside the view's section box are exported; with no section box, all rooms are.

  6. On the Advanced tab, open Entities to be included/excluded from export and check IfcSpace is ticked.

  7. Optional: on Advanced, tick Use 2D room boundaries for room volume for simpler, lighter room shapes.

  8. Select OK, choose where to save the file, and select Export.

Revit only exports levels that have Building Story ticked. Rooms placed on other levels are moved to the next building story below. See Autodesk's IFC Export Setup Options for every setting.

Export from Archicad

Archicad exports Zones as IfcSpace, with Zone Number as the IFC Name and Zone Name as the LongName. Zones usually go missing because the Zone layer is hidden during a visible-elements export, or the translator filters them out.

  1. Go to File > Save as and choose an IFC file type.

  2. In Export, choose Entire project. This ignores layer settings. If you use Visible elements instead, turn on the Zone layer on every story first, because that option exports only what your layers show.

  3. Choose your translator, then check its settings in File > Interoperability > IFC > IFC Translators:

    • Model Filter: set the IFC Domain to All. The Structural and MEP domains leave out Zones.

    • Type Mapping: check your Zone classification maps to IfcSpace. Zones classified as a Spatial Zone export as IfcSpatialZone, which Visibuild does not read as rooms.

  4. In the save dialog, select Filter and check IfcSpace is ticked in the element list.

  5. Save the file.

If the export is slow, check Data Conversion in the translator. IFC Space Containment and IFC Space Boundaries can add a lot of export time, and Visibuild needs neither. See Graphisoft's Filter Model at Export and Model Filter for IFC Export.

Other software

Most architectural tools have a room object that exports as IfcSpace. Make sure it is placed, named and included in the export, then test the file with the IDS below.

Software

Room object

What to check

Vectorworks

Space

Spaces are included in the IFC export and mapped to IfcSpace.

Allplan

Room

Rooms are included in the IFC export.

Bentley OpenBuildings

Space

Spaces are included in the IFC export.

Tekla, structural or services models

None

These models do not hold rooms. Ask for the architectural model instead.

Navisworks

None of its own

A Navisworks file combines other models. Ask for an IFC exported from the architectural model it was built from.

Check the file before you upload

Test every export with the Visibuild IDS file. It runs six quick checks and lists the rooms or levels that need fixing.

An IDS (Information Delivery Specification) is a buildingSMART standard file that lists requirements an IFC model must meet. Any IDS checker can read it.

Editor note: attach visibuild-ifc-spaces.ids here before publishing.

  1. Open your IFC file and the IDS file in an IDS checker. Free options include Sortdesk, which runs in your browser, and IfcTester, an open-source command-line tool. Many model checkers your BIM team already uses also read IDS files.

  2. Run the check. All six specifications should pass. Fix anything that fails, export again and re-check.

Check

What it tests

If it fails

01 The model has a building

An IfcBuilding exists

Re-export the full spatial structure, not a selection of elements.

02 Levels are exported and named

At least one IfcBuildingStorey, each with a name

In Revit, tick Building Story on your levels. Name every level.

03 Rooms are exported as IfcSpace

At least one IfcSpace, each with a room number

If it finds no spaces at all, the export left rooms out. Follow the Revit or Archicad steps above.

04 Every room has a name

Every IfcSpace has a LongName

Fill in the room or zone name on the listed rooms.

05 Every room has 3D geometry

Every IfcSpace has a shape

Close the boundaries of the listed rooms, or place them if they are unplaced.

06 Every room sits on a level

Every IfcSpace belongs to an IfcBuildingStorey

Check the listed rooms are placed on a level that is exported.

Troubleshooting

What you see

Likely cause

Fix

No rooms at all, or Visibuild shows No suggested links

The export left rooms out: a 3D-view export without Export rooms in 3D views, a hidden Zone layer, or rooms mapped to Not Exported

Follow the Revit or Archicad steps above, then re-check with the IDS.

Some rooms are missing

Rooms are unplaced, not enclosed or redundant, belong to another phase, or sit outside the 3D view's section box

Fix the boundaries, set Phase to export, or enlarge the section box.

Extra spaces overlap the rooms

Area plans (GFA, NLA) or area take-off zones exported as spaces

In Revit, set Areas to Not Exported. In Archicad, keep area zones on their own layer and leave it out.

Rooms are on the wrong level, or levels are missing

Levels are not set as building stories

In Revit, tick Building Story on each level and export again.

Rooms appear but few links are suggested

Room numbers and names differ from your location names

Align the naming, or link those locations by hand.

The model has no rooms in the design software

It is a structural, services or coordination model

Ask for the architectural model.

Still stuck? Contact Visibuild support with the IFC file and the IDS checker's report.